Compact power, maximum performance - the GC that does more with less space, less power, and less time.

Experience the future of gas chromatography with 50% smaller footprint, 45% less energy consumption, and ultra-fast 300°C/min temperature ramps for unmatched throughput.
- 50% smaller footprint than traditional GC instruments, saving valuable bench space
- Compact air-bath oven design enables maximum performance in minimal space
Superior Speed & Throughput:
- Ultra-fast temperature ramps up to 300°C/min - significantly faster than conventional systems
- Rapid cool-down capability for shorter cycle times and higher sample throughput
- Backflush technology reduces analysis time while extending column life
Energy Efficiency:
- 45% lower power consumption compared to other GC systems, reducing operating costs and environmental impact
This GC system offers a space-saving footprint that's 50% smaller than traditional GC instruments and uses 45% less power for reduced operating costs. The precisely designed air-bath oven enables rapid temperature ramps up to 300°C/min with fast cool-down for high throughput analysis.
Smart Technology & User Interface
This GC system offers a space-saving footprint that's 50% smaller than traditional GC instruments and uses 45% less power for reduced operating costs. The precisely designed air-bath oven enables rapid temperature ramps up to 300°C/min with fast cool-down for high throughput analysis.
Versatile Configuration Options
The system accommodates multiple inlet types (split/splitless, multimode, purged packed, or cool on-column) and detection options including Agilent mass spectrometers, FID, or TCD. It's compatible with existing 5-inch capillary or packed metal columns and uses familiar consumables and software to minimize training time.
Convenient Access & Sample Introduction
Features a unique top-opening lid for easy column access and side panels for internal component maintenance. Compatible with various automatic samplers (PAL3 Series 2, 7693A, 7650, and 8697 headspace sampler) and includes optional gas/liquid sampling valves and transfer line interface for flexible sample introduction.
Advanced Features
Optional modules include helium conservation for reduced gas usage, hydrogen sensor for safe hydrogen carrier gas operation, and backflush capability that reduces cycle times, maintenance, carryover, and extends column life while improving data quality.
Experience the future of gas chromatography with 50% smaller footprint, 45% less energy consumption, and ultra-fast 300°C/min temperature ramps for unmatched throughput.
- 50% smaller footprint than traditional GC instruments, saving valuable bench space
- Compact air-bath oven design enables maximum performance in minimal space
Superior Speed & Throughput:
- Ultra-fast temperature ramps up to 300°C/min - significantly faster than conventional systems
- Rapid cool-down capability for shorter cycle times and higher sample throughput
- Backflush technology reduces analysis time while extending column life
Energy Efficiency:
- 45% lower power consumption compared to other GC systems, reducing operating costs and environmental impact
This GC system offers a space-saving footprint that's 50% smaller than traditional GC instruments and uses 45% less power for reduced operating costs. The precisely designed air-bath oven enables rapid temperature ramps up to 300°C/min with fast cool-down for high throughput analysis.
Smart Technology & User Interface
This GC system offers a space-saving footprint that's 50% smaller than traditional GC instruments and uses 45% less power for reduced operating costs. The precisely designed air-bath oven enables rapid temperature ramps up to 300°C/min with fast cool-down for high throughput analysis.
Versatile Configuration Options
The system accommodates multiple inlet types (split/splitless, multimode, purged packed, or cool on-column) and detection options including Agilent mass spectrometers, FID, or TCD. It's compatible with existing 5-inch capillary or packed metal columns and uses familiar consumables and software to minimize training time.
Convenient Access & Sample Introduction
Features a unique top-opening lid for easy column access and side panels for internal component maintenance. Compatible with various automatic samplers (PAL3 Series 2, 7693A, 7650, and 8697 headspace sampler) and includes optional gas/liquid sampling valves and transfer line interface for flexible sample introduction.
Advanced Features
Optional modules include helium conservation for reduced gas usage, hydrogen sensor for safe hydrogen carrier gas operation, and backflush capability that reduces cycle times, maintenance, carryover, and extends column life while improving data quality.
- Yes (backflush)
- 1
- No
- Premium
- Autonomous, hands-free
- Single quadrupole
- Triple quadrupole
- 1
- 300 °C/min (120 V std oven is limited to 120 °C/min and 120 V fast oven is limited to 200 °C/min)
- +4 above ambient to 350 °C
- 350 °C to 50 °C in less than 2.5 minutes (22 °C ambient)
- <0.5% RSD
- <0.008%
- 0.001 psi
- 1
- Up to 3
- No
- Standard
- Standard (manually cap septum purge)
- Single quadrupole (stainless steel source)
- Up to 2
- Dimensions: 28.3 cm x 58.5 cm x 49.2 cm
- Minimum required electrical supply: 115/220V
Wasson-ECE Instrumentation
101 Rome Ct., Fort Collins, Colorado USA 80524
Phone: +1 (970) 221-9179
Fax: +1 (970) 221-9364
© 2025. All Rights Reserved.